Installation
 
Sanichasse is a WC suite with a 6-litre flush and built-in small-bore evacuation system. Handwash basin and shower can be connected.

The unit pumps waste up to 5m vertically or 100m horizontally to soil stack or sewer, through 22mm (3/4") copper or CPVC pipework.

Cistern Connection

Electrical Connection
All wiring should conform to the rules of the Institution of Electrical Engineers. The unit requires a 230/240 V single phase AC 50 Hz supply (UK specifications).

Do not connect the unit to a conventional plug and socket, but wire itinto a fused, unswitched fixed wiring connector fitted with a 5 Amp fuse.

The unit has an earth wire. The wires in the mains lead are coloured in accordance with the following code:

  • Brown : Live
    Blue : neutral
    Green/yellow : earth
  • All work on cable, pressure chamber and motor should only be undertaken by qualified SANIFLO servicing personnel, since special tools are needed.