| 1. Attach the head of
the jubilee clip to the ring section |
 |
| 2. Pull the flexible
sleeve over the pan spigot |
 |
| 3. Position the
jubilee clip over the edge of the flexible sleeve and tighten
with a screwdriver |
 |
| Connection of the discharge pipework

Insert the elbow into the exit
pipe from the unit, and turn it to the direction required. Fit
the non- return valve to the other end.
WARNING: The non-return
valve should be positioned so that the embossed arrow is on
the top, and pointing in the direction of flow. Connect the
discharge pipework directly onto the non-return valve in
o22mm. Alternatively, cut back the end of the non-return valve
and fit 32mm discharge pipework.
Secure both ends of the
non-return valve with jubilee clips. |
| WARNING: All
vertical lifts should rise as directly above the unit as
possible. Only one vertical lift is permitted (within 30cm of
the unit). From the high point a 1:200 fall should be
installed. A second lift is not allowed. |
 |
| WARNING: Bends
should be smooth, and not 90o elbows. Either a
copper pulled bend, or in plastic, 2 45o bends
fitted together in series. |
 |
| Connection of washbasin to top
entry |
 |
| Connection of extra sanitary appliances to low
entry

- Use the flexible connector to
connect the shower waste to one of the side inlets. Secure
with plastic clips. Plug the unused inlet with blanking plug
after greasing the joints.
- WARNING: Ensure when
connecting a shower to the SANIPRO XR that the underside of
the shower tray is raised by at least 12mm from the
floor.
|
 |
 |
| |
|