1. Installation next to the shower
tray


ELECTRICAL
INSTALLATION
The electrical installtion
should be carried out by a qualified person. All wiring must conform
to BS7671 - Requirements for Electrical Installation
The mains lead wiring colour
code is as follows:
CONNECTION OF
INLET
Connect the wider end of the
flexible connector to the Sanishower side inlet. The other end
should be connected to the 40mm waste pipe from the shower tray. Use
the plastic Herbie clips. Tighten clip with a pair of pliers.
Warning: When
connecting a shower please make sure that the underside of the
shower tray is at least 6 cm above floor level.
COMMISSIONING THE
UNIT
- First recheck all the
electrical and water connections
- Fill the handbasin with
water, release the plug and check for leaks at
connection.
- Turn on the shower and
allow to run for several minutes at the maximum flow rate and
temperature required for nomal use. Ensure there are no
leaks.
Warning: Do not close
access panel until this has been checked
2. Installation
underneath the shower tray

This type of installation
should only be carried out by a qualified person. The shower tray
must be raised so as to allow 145mm to accomodate the
Sanishower.
Warning: It is important
that an access panel of minimum length 400mm and height 145mm is
provided for possible maintenance of the unit. A screwdriver or
other tool should be required to open the access panel.
See Electrical Connection
above
CONNECTION OF THE SHOWER TRAY TO THE
SIDE INLET
When siting the unit underneath the
shower tray, we recommend that you use a fexible pipe for the shower
waste (eg: JollyFlex). This is so that the unit can be moved from
under the tray for possible maintenance without undoing any of the
original waste connections.
The waste pipe should be connected to
the Sanishower using the flexible 40mm rubber connector.
See Commissioning the Unit
above.
|