Installation

1. Installation next to the shower tray


ELECTRICAL INSTALLATION

The electrical installtion should be carried out by a qualified person. All wiring must conform to BS7671 - Requirements for Electrical Installation

The mains lead wiring colour code is as follows:

BROWN = LIVE
BLUE = NEUTRAL
GREEN/YELLOW = EARTH

CONNECTION OF INLET

Connect the wider end of the flexible connector to the Sanishower side inlet. The other end should be connected to the 40mm waste pipe from the shower tray. Use the plastic Herbie clips. Tighten clip with a pair of pliers.

Warning: When connecting a shower please make sure that the underside of the shower tray is at least 6 cm above floor level.

COMMISSIONING THE UNIT

  1. First recheck all the electrical and water connections
  2. Fill the handbasin with water, release the plug and check for leaks at connection.
  3. Turn on the shower and allow to run for several minutes at the maximum flow rate and temperature required for nomal use. Ensure there are no leaks.

Warning: Do not close access panel until this has been checked

2. Installation underneath the shower tray

This type of installation should only be carried out by a qualified person.
The shower tray must be raised so as to allow 145mm to accomodate the Sanishower.

Warning: It is important that an access panel of minimum length 400mm and height 145mm is provided for possible maintenance of the unit.
A screwdriver or other tool should be required to open the access panel.

See Electrical Connection above

CONNECTION OF THE SHOWER TRAY TO THE SIDE INLET

When siting the unit underneath the shower tray, we recommend that you use a fexible pipe for the shower waste (eg: JollyFlex). This is so that the unit can be moved from under the tray for possible maintenance without undoing any of the original waste connections.

The waste pipe should be connected to the Sanishower using the flexible 40mm rubber connector.

See Commissioning the Unit above.